Development of synthetic nerve endings for axo-axonal transport and testing as acetylcholine ion pump = (Record no. 200428236)

MARC details
000 -LEADER
fixed length control field 06709 a2200409 4500
001 - CONTROL NUMBER
control field 200425247
003 - CONTROL NUMBER IDENTIFIER
control field TR-AnTOB
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230908000935.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161109s2016 tu 000 0
040 ## - CATALOGING SOURCE
Original cataloging agency TR-AnTOB
Language of cataloging eng
Description conventions rda
Transcribing agency TR-AnTOB
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title İngilizce
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number TEZ TOBB FBE MNT YL’17 ABD
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Abdullayeva, Nazrin
9 (RLIN) 118482
245 10 - TITLE STATEMENT
Title Development of synthetic nerve endings for axo-axonal transport and testing as acetylcholine ion pump =
Remainder of title Akso-aksonal iletim için sentetik sinir uçları geliştirilmesi ve asetilkolin iyon pompası olarak test edilmesi /
Statement of responsibility, etc. Nazrin Abdullayeva.
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Ankara :
Name of producer, publisher, distributor, manufacturer TOBB ETÜ Fen Bilimleri Enstitüsü,
Date of production, publication, distribution, manufacture, or copyright notice 2017.
300 ## - PHYSICAL DESCRIPTION
Extent xvii 48 pages :
Other physical details charts, graphics, illustrations (some color) ;
Dimensions 30 cm.
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
Content type code txt
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
Media type code n
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
Carrier type code nc
502 ## - DISSERTATION NOTE
Dissertation note Tez (Yüksek Lisans)--TOBB ETÜ Fen Bilimleri Enstitüsü Nisan 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note
520 ## - SUMMARY, ETC.
Summary, etc. Günümüzde 450 milyondan fazla insan, tedavi edilemeyen nörolojik hastalıklardan küresel olarak muzdarip. Bu hastalıklar, sinir sisteminde bozulmuş elektriksel ve nörokimyasal sinyallerden kaynaklanır. Dünya çapında bu sorunun farkındalığı henüz kazandırılamadı ve bugüne kadar kesin bir tedavi yöntemi bulunamadı. Nörolojik bozukluklarla ilişkili tedavilerin çoğu tıbbi terapi veya elektrik stimülasyonu gibi tedavi yöntemleridir. Bu tedavi yöntemlerinden elde edilen sonuçlar ise maalesef geçici süreliğine etkilidir. Çalışmamızda, bu problemi göz önüne alarak, bir sinir hücresinin işlevini çoğaltan ve sinir sisteminin kusurlu elektrokimyasal iletiminin tamir edilmesine yardımcı olan bir biyomimetik sistemi sunmaktayız. Sinir uyarıları, sinapslar boyunca sinir iletici olarak adlandırılan asetilkolin molekülleri tarafından iletilir. Asetilkolin molekülleri, veziküllerin akson ayağında bulunur. Asetilkolin'in sinaptik yarık içine salınmasından sonra, postsinaptik nöron üzerinde bulunan kolinerjik reseptörlere bağlanır ve postsinaptik hücreler üzerinde uyarılma veya inhibisyona aracılık eder ve bu şekilde sinir sinyalinin taşınmasına neden olur. Grubumuz tarafından geliştirilen sistem, üzerinde PEDOT:PSS bulunan iki elektrot ve yalıtılmış, sadece iyonik taşınmaya izin veren 2 mm'lik aşırı okside bölgeye sahiptir . Esnek yüzeyler üzerinde konjuge polimerlerin (PEDOT:PSS) kaplanmasının kolay ve etkili bir yöntemi kullanılarak, organik biyoelektronik cihazlar için yeni bir tasarım geliştirilmiştir. FTIR ve Raman ölçümleri, PEDOT:PSS elektrotlarını ayıran ve iyonik iletime izin veren elektrokimyasal aşırı oksidasyon bölgesinin başarıyla elde edildiğini göstermiştir. Asetilkolin iyonlarının 4.81x1017 kadarına tekabül eden en yüksek akım yoğunluğunun 54 Scm-1 elektriksel iletkenliği olarak gözlemlenen yaklaşık 41 μAcm-2 idi. Organik elektronik iyon pompası performansları bu denge iletkenlik değerinin çok ötesinde değişmedi. Nafion ™, iyonik iletkenliği arttırmak için uygulandığında ise, denge akım yoğunluğu yaklaşık on kat artmış ve 408 μAcm-2'ye ulaşmıştır. Bu nedenle, OEIP performansının esas olarak iyonik iletkenlik ile ölçeklendiği gösterilmiştir. Yakın gelecekte zahmetsizce seri üretim yapmalarını sağlamak için, organik biyoelektronik üretimi basit bir yöntem önerilmiştir.<br/><br/>Currently, more than 450 million people are globally suffering from some types of neurological diseases that can hardly be treated. These diseases are caused by distorted electrical and neurochemical signaling in the nervous system. The awareness of this worldwide problem is not brought in yet and definitive treatment has not been introduced so far. Most of therapies associated with neurological disorders are based on medical treatment such as medical therapy or electric stimulation. However, results are temporary and ineffective. The major effect obtained so far, was to conceal the disease and this was just not enough. In our study, by taking into consideration this problem we are presenting a biomimetic system that duplicates the function of a neural cell and helps to reinstitute the defective electrochemical transport of nervous system. Nerve impulses are communicated across synapses by diffusible molecules called neurotransmitters, of which one is acetylcholine. Acetylcholine molecules are contained in the axon foot inside vesicles. After the release of acetylcholine into the synaptic cleft, it binds to the cholinergic receptors located on the postsynaptic neuron and mediate excitation or inhibition on postsynaptic cells and thus causing the transportation of neural signal. The system developed by our group resembles a two electrode structure with PEDOT:PSS deposited on them and a tiny 2 mm overoxidized region that cuts off electrical conductivity thus allowing only ionic transport. By using an easy and effective method of depositing conjugated polymers (PEDOT:PSS) on flexible substrates, a new design for organic bioelectronic devices has been developed. FTIR and Raman measurements have demonstrated that electrochemical overoxidation region which separates the PEDOT:PSS electrodes and allows ionic conduction has been achieved successfully. The influence of both electrical and ionic conductivities on organic electronic ion pump (OEIP) performances has been studied. The highest equilibrium current density, which corresponds to 4.81x1017 number of ions of acetylcholine was about 41 μA cm-2 observed for the OEIP with the electrical conductivities of 54 Scm-1. The OEIP performances were not changed much beyond this threshold electrical conductivity. Once Nafion™ has been applied for enhancing the ionic conductivity, the equilibrium current density increased about ten times and reached up to 408 μAcm-2. Therefore, it has been demonstrated that the OEIP performance mainly scales with the ionic conductivity. A straightforward method of producing organic bioelectronics is proposed here giving rise to their effortless mass production in the near future.<br/>
650 00 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 32546
Topical term or geographic name entry element Tezler, Akademik
Topical term or geographic name entry element Dissertations, Academic
9 (RLIN) 32543
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term İon pump
Uncontrolled term Electrically conductive polymers
Uncontrolled term PEDOT: PSS
Uncontrolled term İonomers
Uncontrolled term İyon pompası
Uncontrolled term Elektriksel iletken polimerler
Uncontrolled term PEDOT: PSS
Uncontrolled term İyonomerler
710 #2 - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element TOBB Ekonomi ve Teknoloji Üniversitesi.
Subordinate unit Fen Bilimleri Enstitüsü
9 (RLIN) 77078
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://tez.yok.gov.tr/">https://tez.yok.gov.tr/</a>
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Source of classification or shelving scheme Other/Generic Classification Scheme
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Total Checkouts Full call number Barcode Date last seen Date shelved Koha item type
    Other/Generic Classification Scheme Ödünç Verilemez-Tez / Not For Loan-Thesis Tezler Merkez Kütüphane Merkez Kütüphane Tez Koleksiyonu / Thesis Collection 21/12/2017 Bağış / Donation   TEZ TOBB FBE MNT YL’17 ABD TZ00763 21/12/2017 21/12/2017 Thesis
Devinim Yazılım Eğitim Danışmanlık tarafından Koha'nın orjinal sürümü uyarlanarak geliştirilip kurulmuştur.