Aktif tıbbi cihazlarda fonksiyonel güvenlik gerekliliklerinin incelenmesi / (Record no. 200437826)

MARC details
000 -LEADER
fixed length control field 06377nam a2200457 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field TR-AnTOB
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230908000946.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171111s2019 xxu e mmmm 00| 0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number (TR-AnTOB)200437826
040 ## - CATALOGING SOURCE
Original cataloging agency TR-AnTOB
Language of cataloging eng
Description conventions rda
Transcribing agency TR-AnTOB
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Türkçe
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number TEZ TOBB FBE BMM YL’19 SEV
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Sevim, Ümit
Relator term author
9 (RLIN) 67473
245 10 - TITLE STATEMENT
Title Aktif tıbbi cihazlarda fonksiyonel güvenlik gerekliliklerinin incelenmesi /
Statement of responsibility, etc. Ümit Sevim ; thesis advisor Osman Eroğul.
246 11 - VARYING FORM OF TITLE
Title proper/short title Investigation of functional safety requirements in active medical devices
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Ankara :
Name of producer, publisher, distributor, manufacturer TOBB ETÜ Fen Bilimleri Enstitüsü,
Date of production, publication, distribution, manufacture, or copyright notice 2019.
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 75 pages :
Other physical details illustrations ;
Dimensions 29 cm
336 ## - CONTENT TYPE
Source rdacontent
Content type code txt
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type code n
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type code nc
Carrier type term volume
502 ## - DISSERTATION NOTE
Dissertation note Tez (Yüksek Lisans)--TOBB ETÜ Fen Bilimleri Enstitüsü Aralık 2019
520 ## - SUMMARY, ETC.
Summary, etc. Aktif tıbbi cihazlarda tehlike riski taşıyan fonksiyonlar, programlanabilir elektrikli tıbbi sistemler kullanılarak önleniyor ise bu kontrol sistemlerinde oluşacak hataların kabul edilemez riske yol açmaması gerekmektedir. IEC 60601-1 ve özel cihaz standartları programlanabilir elektrikli tıbbi sistemlerinin(PEMS) geliştirilmesi ve hayata geçirilmesi için gereklilikleri tanımlamış, cihazın risk taşıyan fonksiyonlarının koruyucu sistemler tarafından otomatik olarak yerine getirilmesini talep etmektedir. Ayrıca, Tıbbi Cihaz Yönetmeliği de tıbbi cihazlardaki programlanabilen elektronik sistemlerin süreklilik, güvenilirlik ve performans şartları sağlanacak şekilde tasarlanmasını şart koşmaktadır. Öncelikle Tıbbi Cihaz Yönetmeliği ve standartlarında güvenilirlik şartlarının nasıl açıklandığı bu tez kapsamında incelenmiştir. Tıbbi cihaz standartlarında programlanabilir kontrol sistemleri için istenilen güvenilirlik sağlama kriterlerinin, fonksiyonel güvenlik standartları ile eşleştiği tespit edilmiştir. Ancak tıbbi cihaz standartlarında kontrol sisteminin güvenlik bütünlük seviyesinin (SIL) ne olması gerektiği ve tasarımında kullanılacak tekniklerin açıklamadığı tespit edilmiştir. Bu doğrultuda otomotiv sanayi, proses güvenliği ve nükleer enerji santralleri de dahil olmak üzere emniyet kritik uygulamaların tamamında kullanılan fonksiyonel güvenlik standartlarının aktif tıbbi cihaz ürün geliştirme süreçlerinde de kullanılması ile tıbbi cihazların güvenilirliğinin sağlanacaktır. Kontrol sistemlerini oluşturan donanımların fonksiyonel güvenliği için sistematik hatalar ve rastgele donanım arızaları incelenerek, güvenilirlik hesaplamasının nasıl yapılacağı açıklanmıştır. 1oo1, 1oo2, 2oo2, 1oo2D ve 2oo3 mimari yapıları için IEC 61508 standardına göre güvenilirlik blok diyagramı metodu kullanılarak elde edildi. Daha sonra, rastgele donanım arızaları için bileşenlerin hata modları ve hata oranları kullanılarak SIL hesaplamasında kullanılacak hata oranlarının Hata Türü ve Etkileri Analizi (FMEA) ile nasıl elde edileceği açıklanmıştır. Donanım mimari yapıları için her bir alt sistemin hata olasılığının hesaplanması için MATLAB'da bir program geliştirilmiş ve örnek hata olasılıkları hesaplanmıştır. Daha sonra elde edilen değerler kullanılarak örnek bir kontrol sisteminin güvenilirlik seviyesinin nasıl artırılabileceği gösterilmiştir.
Summary, etc. If functions with risk of danger in active medical devices are prevented by using programmable electrical medical systems, faults in these control systems must not lead to an unacceptable risk. IEC 60601-1 and particular device standards define the requirements for the development and implementation of programmable electrical medical systems, requiring that the safety functions of the device shall be carried out automatically by the protective systems. In addition, 2017/745 numbered Medical Device Regulation requires that the programmable electronic systems in medical devices shall be designed to ensure continuity, reliability and performance. This thesis examines how the reliability requirements of Medical Device Regulations and standards are explained. It has been determined that the reliability criteria required for programmable control systems in medical device standards match the functional safety standards. However, it has been determined that the safety integrity level (SIL) of the control system and the techniques to be used in the design of the medical device standards do not explained. In this respect, the reliability of active medical devices will be ensured by using functional safety standards used in all safety critical applications including automotive industry, process safety and nuclear power plants. For functional safety of the hardware, the systematic errors and random hardware failures are examined and the method of reliability calculation is explained. For the architectural structures 1oo1, 1oo2, 2oo2, 1oo2D and 2oo3, the failure probabilities obtained using the reliability block diagram method according to IEC 61508. Then, it is explained how to obtain the failure rates to be used in SIL calculation by using failure modes and failure rates of components for random hardware failures according to Failure Mode and Effects Analysis(FMEA). A program was developed in MATLAB to calculate the failure probability of each subsystem according to hardware architecture and failure probabilities was calculated. Then, using the calculated failure probabilities, it was shown how to increase the reliability level of a sample control system.
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tezler, Akademik
9 (RLIN) 32546
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Fonksiyonel güvenlik
Uncontrolled term Aktif tıbbi cihaz
Uncontrolled term Programlanabilir elektrikli tıbbi sistem
Uncontrolled term Güvenlik bütünlük seviyesi
Uncontrolled term IEC 61508
Uncontrolled term IEC 60601
Uncontrolled term Functional safety
Uncontrolled term Active medical device
Uncontrolled term Programmable electrical medical system
Uncontrolled term Safety integrity level
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Eroğul, Osman
Relator term advisor
9 (RLIN) 126315
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element TOBB Ekonomi ve Teknoloji Üniversitesi.
Subordinate unit Fen Bilimleri Enstitüsü
9 (RLIN) 77078
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://tez.yok.gov.tr/">https://tez.yok.gov.tr/</a>
Materials specified Ulusal Tez Merkezi
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Source of classification or shelving scheme Other/Generic Classification Scheme
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Total Checkouts Full call number Barcode Date last seen Copy number Date shelved Koha item type
    Library of Congress Classification Ödünç Verilemez-Tez / Not For Loan-Thesis Tezler Merkez Kütüphane Merkez Kütüphane Tez Koleksiyonu / Thesis Collection 26/02/2020 Bağış / Donation   TEZ TOBB FBE BMM YL’19 SEV TZ01100 26/02/2020 1 24/06/2020 Thesis
Devinim Yazılım Eğitim Danışmanlık tarafından Koha'nın orjinal sürümü uyarlanarak geliştirilip kurulmuştur.