İntramedüller çivilerin biyomekanik özelliklerinin deneysel olarak ve sonlu elemanlar yöntemi ile belirlenmesi / (Record no. 200447870)

MARC details
000 -LEADER
fixed length control field 09409nam a2200529 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field TR-AnTOB
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230908000958.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171111s2021 xxu e mmmm 00| 0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number (TR-AnTOB)200447870
040 ## - CATALOGING SOURCE
Original cataloging agency TR-AnTOB
Language of cataloging eng
Description conventions rda
Transcribing agency TR-AnTOB
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Türkçe
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number TEZ TOBB FBE MAK Ph.D’21 ÖZK
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Özkaya, Mustafa
Relator term author
9 (RLIN) 120575
245 10 - TITLE STATEMENT
Title İntramedüller çivilerin biyomekanik özelliklerinin deneysel olarak ve sonlu elemanlar yöntemi ile belirlenmesi /
Statement of responsibility, etc. Mustafa Özkaya ; thesis advisor Teyfik Demir.
246 11 - VARYING FORM OF TITLE
Title proper/short title Determination of the biomechanical properties of intramedullary nails by experimental and numerical methods
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Ankara :
Name of producer, publisher, distributor, manufacturer TOBB ETÜ Fen Bilimleri Enstitüsü,
Date of production, publication, distribution, manufacture, or copyright notice 2021.
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 144 pages :
Other physical details illustrations ;
Dimensions 29 cm
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Media type code n
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Carrier type code nc
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Tez (Doktora Tezi)--TOBB ETÜ Fen Bilimleri Enstitüsü Aralık 2021
520 ## - SUMMARY, ETC.
Summary, etc. İntramedüller çivileme uzun kemik kırıklarının tedavisinde cerrahlar tarafından sıklıkla tercih edilen bir sabitleme yöntemidir. Standart kilitli intramedüller çivilemede, distal kilitleme için standart olarak kullanılan kortikal kilitleme vidalarının dezavantajlarının önüne geçmek için farklı distal kilitleme sistemlerinin geliştirilmesi yönünde çalışmalar mevcuttur. Bu tezde, farklı distal kilitleme yöntemlerine sahip intramedüller çivilerin mekanik davranışları deneysel ve nümerik olarak incelenmiş ve distal kortikal kilitleme vidası kullanımını ortadan kaldıran yeni bir alternatif çivi tasarımının geliştirilmesi ve mekanik özelliklerinin nümerik yöntemlerle belirlenmesi yönünde araştırmalar yapılmıştır. İlk olarak standart kilitli, pençe mekanizmalı ve yeni genişleyebilir kama kilitli intramedüller çivinin subtrokanterik kırığa sahip femur üzerinde yapılan sabitlemelerinin mekanik davranışları, basit sonlu elemanlar analizleri ile karşılaştırılmış ve genişleyebilir kama kilitli intramedüller çivinin güvenli bir sabitleme sağladığı görülmüştür. Ardından, yapılan detaylı parametrik sonlu elemanlar analizleriyle, genişleyebilir kama kilitli intramedüller çivi sabitlemesinde, sabitleme güvenliğini etkileyen bağlantı parametrelerinin uygun değerleri belirlenmiş ve kama sıkma torkunun 3 Nm ve kama-kemik ara yüzünde sürtünme katsayısının 0,7 olduğu modelin en güvenli model olduğu görülmüştür. Tez kapsamında yapılan deneysel çalışmalarda, standart kilitli ve pençe mekanizmalı intramedüller çivilerin subtrokanterik ve intertrokanterik kırık sabitlemelerinin mekanik özellikleri basma yükleri altında incelenmiştir. Standart distal kilitli çivilerin, pençe mekanizmalı çivilere göre daha yüksek yüklere dayandığı ve daha yüksek direngenlik sergiledikleri görülmüştür. Deneylerin ardından, deneylerde incelenen sabitlemelerin sonlu elemanlar modelleri deneysel verilerle doğrulanmıştır. Sonlu elemanlar modellerinin doğrulanmasında, doğrulama parametresi olarak deneylerde numuneler üzerinden alınan gerinim değerleri ve sabitleme direngenlikleri kullanılmıştır. Subtrokanterik kırık sabitlemelerinin doğrulanmış modelleriyle gerinim değerleri en fazla % 10 civarı bir hatayla tahmin edilebilmektedir. Öte yandan nümerik çalışmadan elde edilen direngenlik değerinin deneysel direngenliğe göre yüksek olduğu gerçeği göz önünde bulundurulmalıdır. İntertrokanterik kırık içinse direngenlik, % 5'in altında bir hatayla tahmin edilebilmektedir. Neon sabitlemesinde iki numaralı gerinim ölçerden alınan gerinim değeri göz ardı edildiğinde, gerinim tahminleri de en fazla % 15 civarı bir hata ile yapılabilmektedir. Tezde, doğrulanmış sonlu elemanlar modelleri üzerinden, genişleyebilir kama kilitli intramedüller çivinin subtrokanterik ve intertrokanterik kırık sabitlemelerinin analizleri yapılmış ve mekanik davranışı incelenmiştir. Tezden çıkarılacak en önemli sonuç; tez kapsamında önerilen, tasarımı detaylandırılan ve mekanik davranışı nümerik yöntemlerle incelenen genişleyebilir kama kilitli intramedüller çivi sabitlemesinin, standart kilitli intramedüller çivi sabitlemesine yeni bir alternatif olarak kullanılabileceğidir. Ancak bunu net bir şekilde söylemek için ileri planda yapılacak deneysel çalışmalar gereklidir. Tezden çıkarılabilecek önemli bir diğer sonuç ise; uzun kemik kırıklarının Navy çivisi ile sabitlenmesi yapılırken, özellikle yüksek kemik kalitesine sahip bireyler için pençelerin tamamen kortikal kemik ile temas edecek şekilde açılması, pençelerin kemiğe kayda değer bir miktarda saplanması ve femurun distal üçte birinde pençeli distal kilitleme tercihinden kaçınılması gerektiğidir.
Summary, etc. Intramedullary nailing is a fixation method which has been often preferred by surgeons in the treatment of long bone fractures. There are studies to develop different distal locking system in order to avoid the disadvantages of cortical locking screws which are used as a standard for distal locking of standard intramedullary nailing. In this thesis, the mechanical behavior of intramedullary nails with different distal locking system was investigated experimentally and numerically, and research was conducted to develop a new alternative nail design that eliminates the use of distal cortical locking screw and to determine its mechanical properties by numerical methods. Firstly, the mechanical behavior of standard locking intramedullary nail, clawed intramedullary nail and new expandable wedge locked intramedullary nail on the femur with subtrochanteric fracture were compared with simple finite element analyzes and it was observed that the expandable wedge locked intramedullary nail provided a secure fixation. Afterwards, with the detailed parametric finite element analyzes, the appropriate values of the connection parameters affecting the fixation safety in the expandable wedge-locked intramedullary nail fixation were determined and it was seen that the model with a wedge tightening torque of 3 Nm and a friction coefficient of 0.7 at the wedge-bone interface was the safest model. In the experimental studies carried out within the scope of the thesis, the mechanical properties of the fixations of standard locking and clawed intramedullary nails on subtrochanteric and intertrochanteric fractured femurs were examined under compression loads and it was concluded that standard locking nails withstand higher loads and exhibit higher stiffness than clawed nails. Following the experiments, the finite element models of the fixations examined in the experiments were validated with the experimental data. In the validation of the finite element models, experimental strains and fixation stiffnesses taken from the samples were used as validation parameters. With validated models of subtrochanteric fracture fixation, strain values can be estimated with an error of up to 10%. On the other hand, the fact that the stiffness value obtained from the numerical study is higher than the experimental stiffness should be considered. When the strain measurement taken from the second strain gauge in neon fixation is ignored, strain estimations can be made with an error of up to 15%. In the thesis, subtrochanteric and intertrochanteric fracture fixations of the expandable wedge locked intramedullary nail were analyzed via validated finite element models and its mechanical behavior was investigated. The most important conclusion to be drawn from the thesis is that the expandable wedge locked intramedullary nail fixation, which is proposed, detailed in design, and examined by numerical methods, can be used as a new alternative to the standard locking intramedullary nail fixation. However, further experimental studies are required to say this clearly. Another important conclusion that can be drawn from the thesis is that when fixing long bone fractures with Navy nails, especially for individuals with high bone quality, the claws must be completely deployed in contact with the cortical bone and must stick in the bone at a significant amount. Additionally, the preference of distal locking with claws in the distal third of the femur should be avoided.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Intramedüller çivileme
Uncontrolled term Genişleyebilir intramedüller çivi
Uncontrolled term Kendi kendini kilitleyebilen intramedüller çivi
Uncontrolled term Kama kilitli intramedüller çivi
Uncontrolled term Femur kırıkları
Uncontrolled term Subtrokanterik kırık
Uncontrolled term Intertrokanterik kırık
Uncontrolled term Deneysel çalışma
Uncontrolled term Sonlu elemanlar analizleri
Uncontrolled term Intramedullary nailing
Uncontrolled term Expandable intramedullary nail
Uncontrolled term Self-locking intramedullary nail
Uncontrolled term Wedge-locked intramedullary nail
Uncontrolled term Femur fractures
Uncontrolled term Subtrochanteric fracture
Uncontrolled term Intertrochanteric fracture
Uncontrolled term Experimental study
Uncontrolled term Finite element analysis
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Demir, Teyfik
9 (RLIN) 46900
Relator term advisor
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element TOBB Ekonomi ve Teknoloji Üniversitesi.
Subordinate unit Fen Bilimleri Enstitüsü
9 (RLIN) 77078
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Source of classification or shelving scheme Other/Generic Classification Scheme
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Total Checkouts Full call number Barcode Date last seen Copy number Date shelved Koha item type
    Other/Generic Classification Scheme Ödünç Verilemez-Tez / Not For Loan-Thesis Tezler Merkez Kütüphane Merkez Kütüphane Tez Koleksiyonu / Thesis Collection 03/03/2022 Bağış / Donation   TEZ TOBB FBE MAK Ph.D’21 ÖZK TZ01366 03/03/2022 1 03/03/2022 Thesis
Devinim Yazılım Eğitim Danışmanlık tarafından Koha'nın orjinal sürümü uyarlanarak geliştirilip kurulmuştur.